5. Commissioning

5-8

Festo P.BE-MTR-DCI-DN-EN en 1209a

Commissioning (overview)

Chap.

1. Select the drive type and adapt the parameters to your

axis as necessary.

5.2.1

2. Set the following parameters for homing:

– Homing method,
– search speed to reference point,
– positioning speed to axis zero point,

5.2.2

3. Carry out homing.

– In the “fixed stop ...” homing method:

teach an axis zero point ≠ 0.

5.2.3

4. To define the axis zero point and the operating range

teach-in the following axis parameters:

Axis zero offset to reference point

Positive and negative software end positions.

5.2.4

5. Enter multiple positioning sets (target position, posi-

tioning mode, travel speed and accelerations).

5.2.5

6. Perform a test run to test the positioning response of the

axis, the reference coordinates and the operating range.

5.2.6

7. Optimise the positioning set configuration and the refer-

ence coordinate and operating range settings as
necessary.

5.2.5

8. Switch on the Fieldbus interface of the MTR-DCI.

This step may optionally be carried out first.

5.2.7
and
5.4.1

9. To complete the commissioning process refer to the

information relating to operation of the unit.

5.9

Tab. 5/1: Commissioning steps