Festo Электромотор MTR-DCI User Manual
Page 269
Advertising
![background image](/manuals/464457/269/background.png)
B. Reference – Festo DeviceNet and FHPP
B-47
Festo P.BE-MTR-DCI-DN-EN en 1209a
Motor Data
FHPP
1025
1, 3
Array
uint32
rw
Description
Motor-specific data
Serial Number 1025
1
uint32
rw
Serial number of the motor
Time Max. Current 1025
3
uint32
rw
I
2
t time
Permissible duration for the maximum motor current (see Object 6073h).
When the I
2
t-time expires, the current will be limited automatically to the rated
motor current in order to protect the motor (nominal motor current:
PNU 1035 CI object 6075h).
The time specified is device-dependent (for MTR-DCI approx. 20 ms).
Value range: 1 ... 32767
Default: 100 (
Z 2 s)
Note: values which are too high can damage the motor!
CI
6410h