Parameters involved (record structure) – Festo Электромотор MTR-DCI User Manual

Page 164

Advertising
background image

5. Commissioning

5-66

Festo P.BE-MTR-DCI-DN-EN en 1209a

Parameters involved (Record structure)

The entries in the position set table can be written via the
Fieldbus (see Tab. 5/21). Each individual nominal value is
addressed via a dedicated PNU. A record consists of the nom-
inal values with the same subindex.

The composition of the position set table as per FHPP is
described in appendix B.2.8.

Overview of parameters involved (see section B.2.8)

Record structure

Description

FCT

PNU

CI

Absolute/relative positioning

x

401

20E0/01h

Target position

x

404

20E0/02h

Speed

x

406

20E0/03h

Acceleration

x

407

20E0/04h

Start

CPOS.B1 = positive edge: Start
Jogging and homing have priority.

Feedback

SPOS.B2 = 0: Motion complete
SPOS.B1 = positive edge: Acknowledge start
SPOS.B4 = 1: Drive is moving

Requirements

Device control by PLC/Fieldbus.
Controller must be in “Operation enabled” status.
A valid record number is active

Tab. 5/21: Parameters involved in record selection