1. System overview

1-20

Festo P.BE-MTR-DCI-DN-EN en 1209a

Dimensional reference system

e

f

Linear axis with the homing method:
Fixed stop

Rotational axis with the homing method:
Reference switch

REF
AZ
PZ

Homing point (or reference point): point determined during the homing run: reference
switch or stop.
Axis zero point: point of reference for the project zero point and the software end positions.
Project zero point: Reference point (= zero point) for actual position and absolute positions
in the position set table.

a
b, c
d

Axis zero point offset: distance between axis zero point AZ and homing point REF
Software end position offsets: limits for the permitted positioning range (= effective stroke)
Project zero point offset: distance from AZ

e
f

Effective stroke: permitted positioning range
Nominal stroke of the axis used

Tab. 1/6: Dimensional reference system