Festo Электромотор MTR-DCI User Manual
Page 42
![background image](/manuals/464457/42/background.png)
1. System overview
1-20
Festo P.BE-MTR-DCI-DN-EN en 1209a
Dimensional reference system
e
f
Linear axis with the homing method:
Fixed stop
Rotational axis with the homing method:
Reference switch
REF
AZ
PZ
Homing point (or reference point): point determined during the homing run: reference
switch or stop.
Axis zero point: point of reference for the project zero point and the software end positions.
Project zero point: Reference point (= zero point) for actual position and absolute positions
in the position set table.
a
b, c
d
Axis zero point offset: distance between axis zero point AZ and homing point REF
Software end position offsets: limits for the permitted positioning range (= effective stroke)
Project zero point offset: distance from AZ
e
f
Effective stroke: permitted positioning range
Nominal stroke of the axis used
Tab. 1/6: Dimensional reference system