3. Installation

3-18

Festo P.BE-MTR-DCI-DN-EN en 1209a

3.6.3

Fieldbus bit rate and fieldbus length

Note
The maximum permitted length for fieldbus segments de-
pends on the bit rate used. You will find detailed informa-
tion in the manuals for your control system or bus inter-
face or DeviceNet specification.

•

Note the maximum permitted segment length (cable
length without repeater) if you are connecting the MTR-
DCI to a fieldbus segment.

•

Avoid branch lines.

Note

•

Refer to the manuals for your control system or bus in-
terface in order to ascertain which T-adapter and maxim-
um branch line length are permitted for your controller.

•

Also take into account the sum of the branch line lengths
when calculating the maximum permitted length of the
fieldbus cable.

Bit rate

Maximum segment length

500 kbps

100 m

250 kBit/s

250 m

125 kBit/s

500 m

Tab. 3/9: Maximum length of fieldbus segments as a func-

tion of the bit rate

Information on setting the bit rate and further bus paramet-
ers on the control panel can be found in section 5.2.7.