3. Installation
3-18
Festo P.BE-MTR-DCI-DN-EN en 1209a
3.6.3
Fieldbus bit rate and fieldbus length
Note
The maximum permitted length for fieldbus segments de-
pends on the bit rate used. You will find detailed informa-
tion in the manuals for your control system or bus inter-
face or DeviceNet specification.
•
Note the maximum permitted segment length (cable
length without repeater) if you are connecting the MTR-
DCI to a fieldbus segment.
•
Avoid branch lines.
Note
•
Refer to the manuals for your control system or bus in-
terface in order to ascertain which T-adapter and maxim-
um branch line length are permitted for your controller.
•
Also take into account the sum of the branch line lengths
when calculating the maximum permitted length of the
fieldbus cable.
Bit rate
Maximum segment length
500 kbps
100 m
250 kBit/s
250 m
125 kBit/s
500 m
Tab. 3/9: Maximum length of fieldbus segments as a func-
tion of the bit rate
Information on setting the bit rate and further bus paramet-
ers on the control panel can be found in section 5.2.7.