4 description of the i/o data (direct task) – Festo Электромотор MTR-DCI User Manual
Page 133

5. Commissioning
5-35
Festo P.BE-MTR-DCI-DN-EN en 1209a
5.5.4
Description of the I/O data (direct task)
O data – Direct task
Byte
Bit
EN
Description
1
B0 ... B7
CCON
Control bytes, see chapter 5.5.5
2
B0 ... B7
CPOS
3
B0 ... B7
CDIR
4
B0 ... B7
Velocity
Nominal value 1: preselection of velocity in % of the maximum
velocity
5 ... 8
B0...B31
Position
Force, ...
Nominal value 2: preselection depending on the controller mode
of operation (see control byte 3 CDIR)
– Positioning mode: position in increments
– Force mode: force/torque in % of the rated current
O data – Direct task
Byte
Bit
EN
Description
1
B0 ... B7
SCON
Status bytes, see chapter 5.5.6
2
B0 ... B7
SPOS
3
B0 ... B7
SDIR
4
B0 ... B7
Velocity
Force/Torque
Actual value 1: acknowledgement depending on the controller
mode of operation (see control byte 3 CDIR)
– Positioning mode: preselection of speed in % of the
maximum speed
– Force mode: force/torque in % of the rated current.
5 ... 8
B0...B31
Position
Actual value 2: acknowledgement of position in increments