4 description of the i/o data (direct task) – Festo Электромотор MTR-DCI User Manual

Page 133

Advertising
background image

5. Commissioning

5-35

Festo P.BE-MTR-DCI-DN-EN en 1209a

5.5.4

Description of the I/O data (direct task)

O data – Direct task

Byte

Bit

EN

Description

1

B0 ... B7

CCON

Control bytes, see chapter 5.5.5

2

B0 ... B7

CPOS

3

B0 ... B7

CDIR

4

B0 ... B7

Velocity

Nominal value 1: preselection of velocity in % of the maximum
velocity

5 ... 8

B0...B31

Position
Force, ...

Nominal value 2: preselection depending on the controller mode
of operation (see control byte 3 CDIR)
– Positioning mode: position in increments
– Force mode: force/torque in % of the rated current

O data – Direct task

Byte

Bit

EN

Description

1

B0 ... B7

SCON

Status bytes, see chapter 5.5.6

2

B0 ... B7

SPOS

3

B0 ... B7

SDIR

4

B0 ... B7

Velocity

Force/Torque

Actual value 1: acknowledgement depending on the controller
mode of operation (see control byte 3 CDIR)
– Positioning mode: preselection of speed in % of the

maximum speed

– Force mode: force/torque in % of the rated current.

5 ... 8

B0...B31

Position

Actual value 2: acknowledgement of position in increments