6 test run – Festo Электромотор MTR-DCI User Manual

Page 116

Advertising
background image

5. Commissioning

5-18

Festo P.BE-MTR-DCI-DN-EN en 1209a

5. Select [SAVE] to save the positioning set. Only then will

the settings be retained even if the power supply is
switched off or if there is a power failure.

6. Enter the next position record.

Digitalisation errors of the analogue-digital converter can
accumulate in the case of relative position movements which
occur frequently one after the other, leading to deviations of
the position values. If necessary, insert an absolute position
set or a homing run into the positioning cycle, in order to
correct deviations.

5.2.6

Test run

Warning
Injury to persons and damage to property

With all positioning procedures, the motor turns and the
connected axis moves.

Make sure that:

– Nobody can place their hands into the positioning

range,

– There are no objects within the positioning range.

Caution
Damage to components

The unit must not move onto mechanical end positions
(stops) during operation. When the unit moves to the end
positions with a heavy load, blockage may occur in the end
positions

Limit the positioning range by defining valid software
end positions during commissioning (see section 5.2.4).

Advertising