Record Velocity
FHPP
406
1...32
Array
uint32
rw
Description
Speed setpoint in increments/s
Value range
MTR-DCI-...
Value range DMES-...
...-32...-G7
0...66000
Z 0...12 mm/s (DMES-18)
...-32...-G14
Z 0...6.0 mm/s (DMES-18)
...-42...-G7
0...100000
Z 0...18.5 mm/s (DMES-25)
...-42...-G14
Z 0...9.1 mm/s (DMES-25)
...-52...-G7
0...100000
Z 0...29.6 mm/s (DMES-40)
...-52...-G14
Z 0...14.6 mm/s (DMES-40)
...-62...-G7
0...113400
Z 0...50.4 mm/s (DMES-63)
...-62...-G14
Z 0...24.7 mm/s (DMES-63)
...-62...-G22
Z 0...15.3 mm/s (DMES-63)
Default: 0
Record 0 406
1
uint32
rw
Nominal speed value for position set record 0 (homing)
Record ... 406
...
uint32
rw
Nominal speed value for position set record 1 ... 30
Record 31 406
32
uint32
rw
Nominal speed value for position set record 31
CI
20EDh
01h...20h
Array
uint32
rw
Additional subindex of object 20EDh see PNU 531
DeviceNet
68h
01h
…20h
06h
uint32
rw