B. Reference – Festo DeviceNet and FHPP

B-50

Festo P.BE-MTR-DCI-DN-EN en 1209a

Max. Current

FHPP

1034

Var

uint16

rw

Description

Maximum motor current for homing in 1/1000 of the specified nominal current
(see PNU 1035 / 6075h).
In homing mode: Limits the motor force during homing to the stop and - in the
event of an error - protects sensitive stops during homing to a reference switch.
Note:
Note that the current limitation also limits the maximum possible speed and
that (higher) nominal speeds may not therefore be achieved.
Value range: 1 ... 2000 (0x0001 ... 0x07D0)
Default: 1500 (0x05DC)

CI

6073h

00h

Var

uint16

rw

DeviceNet

6Bh

01h

40h

uint16

rw

Motor Rated Current

FHPP

1035

Var

uint32

rw

Description

Nominal motor current in [mA]; see type plate; identical to PNU 1026/3

CI

6075h

00h

Var

uint32

rw

DeviceNet

6Bh

01h

41h

uint32

rw

Motor Rated Torque

FHPP

1036

Var

uint32

rw

Description

Nominal torque of the MTR-DCI in [mNm]

CI

6076h

00h

Var

uint32

rw

DeviceNet

6Bh

01h

42h

uint32

rw