Bit rate (bit rate) – Festo Электромотор MTR-DCI User Manual
Page 119

5. Commissioning
5-21
Festo P.BE-MTR-DCI-DN-EN en 1209a
Bit rate (bit rate)
–
Possible bit rates:
500 kbit, 250 kbit, 125 kbit
–
An
invalid bit rate is preset (display on the control panel:
“???”).
This ensures that a correct bit rate must be set during
commissioning or replacement.
Note
All of the participants on a fieldbus line must use the same
bit rate. Otherwise no communication will be possible.
Set the bit rate as follows:
1. Choose [Settings] [Bus parameter] [Baudrate]
(see also section 4.5).
2. Press <Enter> to display the current setting.
3. Use the arrow keys to set the desired baud rate.
4. Accept the setting with OK <Enter>.
The defined baud rate is permanently saved.
Note
The defined baud rate only takes effect
after a power
off/on cycle!
} Settings
Bus parameter
Baudrate
Baudrate
500 kBd
ESC <Menu>
EDIT <-->
OK <Enter>