5. Commissioning

5-21

Festo P.BE-MTR-DCI-DN-EN en 1209a

Bit rate (bit rate)

Possible bit rates:

500 kbit, 250 kbit, 125 kbit

An

invalid bit rate is preset (display on the control panel:

“???”).
This ensures that a correct bit rate must be set during
commissioning or replacement.

Note
All of the participants on a fieldbus line must use the same
bit rate. Otherwise no communication will be possible.

Set the bit rate as follows:

1. Choose [Settings] [Bus parameter] [Baudrate]

(see also section 4.5).

2. Press <Enter> to display the current setting.

3. Use the arrow keys to set the desired baud rate.

4. Accept the setting with OK <Enter>.

The defined baud rate is permanently saved.

Note
The defined baud rate only takes effect

after a power

off/on cycle!

} Settings

Bus parameter

Baudrate

Baudrate

500 kBd

ESC <Menu>

EDIT <-->

OK <Enter>