B.2.8 record list – Festo Электромотор MTR-DCI User Manual

Page 249

Advertising
background image

B. Reference – Festo DeviceNet and FHPP

B-27

Festo P.BE-MTR-DCI-DN-EN en 1209a

B.2.8

Record list

PNU 400

Record number
uint8

PNU 401

RCB1

1)

uint8

PNU 404

Target position
int32

PNU 406

speed
uint32

PNU 407

Acceleration
uint32

0

Homing

1

...

...

...

...

2

...

...

...

...

...

...

...

...

...

31

...

...

...

...

1) RCB = Record Control Byte. Defines whether positioning is relative or absolute.

Tab. B/3: Position set table structure (record list)

FHPP

The record selection for reading and writing in FHPP is made
via the subindex of the PNUs 401 ... 407. Above PNU 400 the
active record for positioning or teaching is selected.

Record Number

FHPP

400

Var

uint8

rw

Description

The active/selected record. Is also valid even when the drive is not in Record
selection mode (e. g. during teaching). In Record selection mode this para-
meter is transferred to the cyclical I/O data.
Value range: 0 ... 31 (0x00 ... 0x1F)

CI

2033h

– / 00h

Var

uint8

rw

DeviceNet

67h

01h

20h

uint8

rw

Advertising