DeviceNet Reference (Explicit Messaging)

B.1.1

Parameter classes

Class

CLASS

1)

Description

Device data

0x64 (100)

Device identification and device-specific settings, version
numbers, passwords, control panel queries, etc.

Diagnosis Buffer

0x65 (101)

Memory for diagnostic events: fault numbers, fault time,
incoming/outgoing event

Diagnosis Buffer
Administration
(Diagnosis buffer
management)

0x66 (102)

Management of the diagnosis buffer

Process Data

0x67 (103)

Current nominal and actual values, local I/Os, status data,
record number, etc.

Record Sets

0x68 (104)

A record contains all the nominal value parameters required
for a positioning procedure

Project Data

0x69 (105)

Basic project settings. Maximum speed and acceleration,
offset project zero point etc.

--> Parameters are the basis

for the record list

Factor group

0x6A (106)

Reserved

Axis Data

0x6B (107)

All axis-specific parameters for electric drives. Gear ratio,
feed constant, homing parameters ...

System Diagnosis

0x6C (108)

Read or clear the active device fault

Fieldbus diagnosis
Fieldbus diagnostics

0x6D (109)

Current connection status and fieldbus settings, e.g. bit
rate, I/O data length

1) Class number as per DeviceNet specification

Tab. B/1: Parameter classes (DeviceNet)