Festo Электромотор MTR-DCI User Manual
Page 110

5. Commissioning
5-12
Festo P.BE-MTR-DCI-DN-EN en 1209a
Factory settings
32
42
52
62
Speeds v_sw, v_s0
%
1)
inc/s
~41 %
27000
~22 %
22400
~17 %
16800
~15 %
16800
Rated motor speed
rot/s
inc/s
55
66000
50
100000
50
100000
56.7
113400
Homing method
Reference switch, negative (near motor)
1)
% of the nominal motor speed; max. = 50 %
Tab. 5/4: Factory pre-setting for homing parameters
[Hom. paramet.]
Param.
Description
[Homing method]
1)
sw.neg
(switch negative)
Homing to reference switch, positive, negative
sw.pos
(switch positive)
Homing to reference switch, positive
bl.neg
(block negative)
Homing to fixed stop, negative
bl.pos
(block positive)
Homing to fixed stop, positive
[Velocity v_sw]
v_sw
Speed for searching for the homing point
[Velocity v_s0]
v_s0
Speed for moving to the axis zero point
[SAVE...]
Save parameters in EEPROM
1)
Further information on homing methods is provided in chapter 1.6.3.
Tab. 5/5: Homing parameters