Festo Электромотор MTR-DCI User Manual

Page 26

Advertising
background image

1. System overview

1-4

Festo P.BE-MTR-DCI-DN-EN en 1209a

You can parameterise and commission the MTR-DCI as fol-
lows:

Using the FCT software package and the RS232 interface
of your PC.

With the optional control panel with display and 4 operat-
ing buttons (MTR-DCI-...-H2 only).

Over the Fieldbus.

Functions

HMI

FCT

Field bus

Parameter
assignment

Selecting the axis type and the axis para-
meters

Specifying a gear factor (for external
gears)

Uploading/downloading configuration
data

Saving different configurations in projects

x


x

x

x
x

x

x

x

Position records

Compiling a position set table with set
record number, target position, posi-
tioning mode, positioning speed, acceler-
ation

x

x

x

Commissioning

Homing

Jog mode

Teaching positions

Moving in individual steps

Starting and stopping positioning pro-
cedures while commissioning

Extended test functions e.g. status dis-
plays

Testing or demonstrating the position
records

x
x
x

x

(x)

x

x
x
x
x
x

x

x

x
x
x
x
x

x

x

Diagnosis/Service

Reading and displaying diagnostic data

x

x

x

Advertising