4. The control panel (type MTR-DCI-...-H2 only)
4-11
Festo P.BE-MTR-DCI-DN-EN en 1209a
4.4
[Positioning] menu
Warning
Injuries or damage to mechanical components.
With all positioning procedures, the motor turns and the
connected axis starts to move.
•
Make sure that:
– Nobody can place their hands into the positioning
range.
– There are no objects within the positioning range.
Note
•
Before starting a homing run, make sure that:
– The positioning system is set up and wired
completely, and is supplied with power.
– Parameterising is completed.
•
Do not start a positioning run until the reference system
has been defined by homing (see chapter 4.4.3).
Note
Note that position set records with speed v=0 or an invalid
target position (-> fault TARGET POSITION OUT OF LIMIT)
will not be executed.