Festo Электромотор MTR-DCI User Manual
Page 198

6. Diagnosis and error display
6-8
Festo P.BE-MTR-DCI-DN-EN en 1209a
Cate-
gory
Status
bytes
2)
Fault
LED
Fault
number
Device
Error
1)
Description
Name, display
Warning
HOT TEMPERATURE
Temperature too
high
–
–
FLASHING WARN
Warning
COLD TEMPERA-
TURE
Temperature too
low
–
–
FLASHING WARN
1)
See PNU 205 / CI 2FF1/00
2)
For FHPP status bytes, see section 5.5.2
Tab. 6/6: Faults and warnings with fault numbers and fault bits
6.3.2
Description of the messages, warnings, and faults
Messages
Messages give information regarding operating states
Notification
Cause
Attention!
Motor moves...
Message before the start of a positioning move-
ment. After confirmation with the <ENTER> button,
the drive starts moving.
Profile velocity
= 0. Please set
v.
The menu command [Move position set] is not
being executed because the positioning speed of
the position set record is v = 0. Modify the
parameter assignment or select a different
position set record.