Festo Электромотор MTR-DCI User Manual

Page 198

Advertising
background image

6. Diagnosis and error display

6-8

Festo P.BE-MTR-DCI-DN-EN en 1209a

Cate-
gory

Status
bytes

2)

Fault
LED

Fault
number

Device
Error

1)

Description

Name, display

Warning

HOT TEMPERATURE

Temperature too
high

FLASHING WARN

Warning

COLD TEMPERA-
TURE

Temperature too
low

FLASHING WARN

1)

See PNU 205 / CI 2FF1/00

2)

For FHPP status bytes, see section 5.5.2

Tab. 6/6: Faults and warnings with fault numbers and fault bits

6.3.2

Description of the messages, warnings, and faults

Messages

Messages give information regarding operating states

Notification

Cause

Attention!
Motor moves...

Message before the start of a positioning move-
ment. After confirmation with the <ENTER> button,
the drive starts moving.

Profile velocity
= 0. Please set
v.

The menu command [Move position set] is not
being executed because the positioning speed of
the position set record is v = 0. Modify the
parameter assignment or select a different
position set record.

Advertising