5. Commissioning

5-60

Festo P.BE-MTR-DCI-DN-EN en 1209a

1

Ready for teaching

2

Value transferred

1

0

Reset
SPOS.B3

Teach value
CPOS.B5

1

2

1

0

Fig. 5/3:

Handshake when teaching

Note:
The drive does not need to stop moving for teaching. How-
ever, a speed of 1 m/s means that the actual position
changes by 1 mm every millisecond. With the usual cycle
times of PLC + Fieldbus + motor controller, there will still be
inaccuracies of several millimetres even at a speed of only
100 mm/s.

Overview of parameters involved (see sections B.2.8 and B.2.9)

Parameters involved

Description

FCT

PNU

CI

Teach target

1)

520

21FEh

Record number

1)

400

2190h

Start (FHPP)

CPOS.B5 = Falling edge: Teach value

Acknowledgement
(FHPP)

SPOS.B3 = 1: Value transferred

Requirement

Device control by PLC/Fieldbus
Controller must be in status “Operation enabled”

1)

Teaching is made possible in the Festo Configuration Tool by special functions.

Tab. 5/20: Parameters involved in teaching