3. Installation

3-9

Festo P.BE-MTR-DCI-DN-EN en 1209a

Note the following selection criteria for the MTR-DCI power
supply:

The power supply nominal current should be at least the
same as the motor startup current (peak current).

The motor tolerances should be allowed for with 20% -
50% reserve power.

voltage supply

MTR-…-32

MTR-…-42

MTR-…-52

MTR-…-62

Motor nominal current

A

0.73

2

5

6.19

Motor peak current

A

2.1

3.8

7.7

20

Nominal current of power sup-
ply unit

A

≥ 3

≥ 6

≥ 10

≥ 15

1)

External fuse
secondary side

A

5 A
slow-blowing

7 A
slow-blowing

10 A
slow-blowing

25 A
slow-blowing

1)

Exception

Tab. 3/4: Power supply and fuse requirements

1

external fuse

2

Earthing
connection (see
chapter 3.2)

A1

A2

A1

A2

Fig. 3/2:

Connection example – Power supply