4. The control panel (type MTR-DCI-...-H2 only)

4-20

Festo P.BE-MTR-DCI-DN-EN en 1209a

4.5.4

[Settings] [Position set]

Programming the position set table

First select the desired position set number. The following
settings related to the currently selected positioning set.
When performing a homing run, please also note the
explanation in chapter 5.2.5.

[Position set]

Param.

Description

[Position nr.]

Nr

The number of the position set record

[Pos set mode]

[abso-
lute/
relative]

Positioning mode
absolute = absolute position specification, related to the pro-
ject zero point
relative = relative position specification, related to the current
position

[Position]

xt

Teach mode for setting the target position in the selected units of
measurement, e.g. [mm].
Do not teach the positions until the reference system has been
defined by homing. (see chapter 4.4.3).

[Velocity]

v

Positioning speed in the selected system of measurement
e.g. [mm/s]

[SAVE...]

Save parameters in EEPROM

Tab. 4/9: [Settings] [Position set] menu

<- ->

Use the arrow buttons to move the axis to the
desired position or select the parameter setting.

OK

Confirm the selection using the <Enter> button.

ESC

Pressing the <Menu> button cancels the action and
returns you to the higher menu level.

Choose [SAVE...] to save the parameter settings. Only then
will the settings be retained even if the power supply is
switched off or if there is a power failure.