Project data – General
Project Zero Point
FHPP
500
–
Var
int32
rw
Description
Distance from axis zero point to project zero point.
Point of reference for target positions in the position set table (see PNU 404).
Value range: -2
31
...+(2
31
-1). Default: 0
CI
21F4h
00h
Var
int32
rw
DeviceNet
69h
01h
01h
int32
rw
Software End Positions
FHPP
501
1, 2
Array
int32
rw
Description
Software end positions in increments. The offset to the axis zero point is
entered. Target positions outside the end positions are not permitted and will
lead to a fault.
An entry of 0 for both end positions deactivates the software end positions.
Plausibility rule: Min-Limit ≤ Max-Limit
Range of values: -2
31
...+(2
31
-1)
Lower Limit 501
1
int32
Lower software end position. Default: 0
Upper Limit 501
2
int32
Upper software end position. Default: 50 mm
CI
607Bh
01h, 02h
Array
int32
rw
DeviceNet
69h
01h
02h, 03h
int32
rw