Festo Электромотор MTR-DCI User Manual
Page 156
5. Commissioning
5-58
Festo P.BE-MTR-DCI-DN-EN en 1209a
1
Low speed phase 1
(slow travel)
2
Maximum speed for
phase 2
3
Acceleration /
deceleration
4
Duration of phase 1
CPOS.B3 or
CPOS.B4
(jogging
positive/
negative)
Speed v (t)
t [s]
1
0
1
2
3
4
3
Fig. 5/2:
Flow diagram for jogging mode
Overview of parameters involved (see section B.2.9)
Parameters involved
Description
FCT
PNU
CI
Speed of phase 2 in (inc/s)
x
531
20ED/21
Acceleration or deceleration (Inc/s
2
)
x
532
20EE/21
Duration of phase 1 in ms
x
534
20E9/21
Start (FHPP)
CPOS.B3 = positive edge: jogging positive (forwards)
CPOS.B4 = positive edge: jogging negative (backwards)
Feedback (FHPP)
SPOS.B4 = 1: Drive is moving
SPOS.B2 = 0: (Motion Complete)
Requirement
Device control by PLC/Fieldbus
Controller must be in status “Operation enabled”
Tab. 5/18: Parameters involved in jogging mode