6. Diagnosis and error display
6-9
Festo P.BE-MTR-DCI-DN-EN en 1209a
Warnings
Warnings have no effect on the behaviour of the drive. The
cause of the warning should however be eliminated so that it
does not lead to a fault.
When a warning occurs, the fault LED flashes and the output
WARNING is set (FHPP status bits, SCON.B2).
Warning
Cause
HOT
TEMPERATURE
Operating temperature 70°C < T < 80°C,
may need to check whether drive is overloaded,
check the mechanical parts (e.g. for stiffness),
reduce ambient temperature.
COLD
TEMPERATURE
Operating temperature < -10°C,
increase ambient temperature as appropriate.
STANDSTILL-
WARNING
The axis has moved outside the standstill
position window.
ILLEGAL
RECORD
WARNING
Invalid record number.
Fault
If there is a fault, the drive will be stopped. The fault LED will
flash.
1. Eliminate the cause of the fault.
2. Acknowledge the fault message:
–
With <Enter> on the control panel,
–
Via Fieldbus with a falling edge on the ENABLE signal,
–
Via Fieldbus with a rising edge on the RESET signal
CCON.B3,
–
With the “Acknowledge error” button in the Festo
Configuration Tool.