Data Memory Control

FHPP

127

1, 2

Array

uint8

rw

1)

Description

Commands for the EEPROM (non-volatile data storage)

Delete EEPROM 127

1

uint8

rw

When the object has been written, and after Power Off/On, the data in the
EEPROM is reset to the factory settings.
Fixed: 16 (0x10): delete data in the EEPROM and restore factory settings.
Pay attention to the following note.

Save Data 127

2

uint8

rw

The data in EEPROM is overwritten with the current user-specific settings.
Fixed 1 (0x01): save data

CI

20F1h

01h, 02h

Array

uint8

rw

1)

DeviceNet

64h

01h

14h, 15h

uint8

rw

1)

1)

When reading the reply “0” always occurs

Note
All user-specific settings will be lost when the EEPROM is
deleted (except for the cycle number). The status after
deletion corresponds to the standard factory setting.

Always carry out initial commissioning after deleting the
EEPROM.

When the EEPROM is deleted, the field bus parameters
are also reset!