Festo Электромотор MTR-DCI User Manual

Page 242

Advertising
background image

B. Reference – Festo DeviceNet and FHPP

B-20

Festo P.BE-MTR-DCI-DN-EN en 1209a

Data Memory Control

FHPP

127

1, 2

Array

uint8

rw

1)

Description

Commands for the EEPROM (non-volatile data storage)

Delete EEPROM 127

1

uint8

rw

When the object has been written, and after Power Off/On, the data in the
EEPROM is reset to the factory settings.
Fixed: 16 (0x10): delete data in the EEPROM and restore factory settings.
Pay attention to the following note.

Save Data 127

2

uint8

rw

The data in EEPROM is overwritten with the current user-specific settings.
Fixed 1 (0x01): save data

CI

20F1h

01h, 02h

Array

uint8

rw

1)

DeviceNet

64h

01h

14h, 15h

uint8

rw

1)

1)

When reading the reply “0” always occurs

Note
All user-specific settings will be lost when the EEPROM is
deleted (except for the cycle number). The status after
deletion corresponds to the standard factory setting.

•

Always carry out initial commissioning after deleting the
EEPROM.

•

When the EEPROM is deleted, the field bus parameters
are also reset!