Festo Электромотор MTR-DCI User Manual
Page 242

B. Reference – Festo DeviceNet and FHPP
B-20
Festo P.BE-MTR-DCI-DN-EN en 1209a
Data Memory Control
FHPP
127
1, 2
Array
uint8
rw
1)
Description
Commands for the EEPROM (non-volatile data storage)
Delete EEPROM 127
1
uint8
rw
When the object has been written, and after Power Off/On, the data in the
EEPROM is reset to the factory settings.
Fixed: 16 (0x10): delete data in the EEPROM and restore factory settings.
Pay attention to the following note.
Save Data 127
2
uint8
rw
The data in EEPROM is overwritten with the current user-specific settings.
Fixed 1 (0x01): save data
CI
20F1h
01h, 02h
Array
uint8
rw
1)
DeviceNet
64h
01h
14h, 15h
uint8
rw
1)
1)
When reading the reply “0” always occurs
Note
All user-specific settings will be lost when the EEPROM is
deleted (except for the cycle number). The status after
deletion corresponds to the standard factory setting.
•
Always carry out initial commissioning after deleting the
EEPROM.
•
When the EEPROM is deleted, the field bus parameters
are also reset!