2 positioning – Festo Электромотор MTR-DCI User Manual
Page 186

5. Commissioning
5-88
Festo P.BE-MTR-DCI-DN-EN en 1209a
5.8.2
Positioning
The following always applies:
Transitions T4, T6 and T7* always have priority.
TA
Internal conditions
Actions of the user
TA1
Homing has been carried out.
Start positioning task = 0
→ 1
Halt = 1
CCON = xxx0.xx11
CPOS = 0xx0.00P1
TA2
Motion Complete = 1
The current record has been completed. The
next record is not to be executed automatically
“Halt” state is any
CCON = xxx0.xx11
CPOS = 0xxx.xxx0
TA3
Motion Complete = 0
Halt = 1
→ 0
CCON = xxx0.xx11
CPOS = 0xxx.xxx0
TA4
Halt = 1
Start positioning task = 0
→ 1
Clear remaining positioning = 0
CCON = xxx0.xx11
CPOS = 00xx.xxP1
TA5
Record selection:
–
An individual record has been completed.
–
The next record is to be executed automati-
cally.
CCON = xxx0.xx11
CPOS = 0xxx.xxx1
Direct task:
–
A new positioning task has arrived.
CCON = xxx0.xx11
CPOS = 0xxx.xx11
TA6
Clear remaining positioning = 0
→ 1
CCON = xxx0.xx11
CPOS = 01xx.xxxx
TA7
Start homing = 0
→ 1
Halt = 1
CCON = xxx0.xx11
CPOS = 0xx0.0Px1
Key: P = positive edge, N = negative edge, x = any