Refer to, For a list of alarm codes, Minor faults and alarms – Yaskawa Z1000U HVAC Matrix Bypass User Manual

Page 233

Advertising
background image

HOA

Keypad

Display

Name

Page

ov

Control Circuit Overvoltage

248

SCF

Safety Circuit Fault

248

SEr

Too Many Speed Search Restarts

248

SoH

Snubber Discharge Resistor Overheat

248

SrC

Phase Order Detection Fault

248

Srr

Internal Resistance Fault

249

SvE

Zero Servo Fault

249

TdE

Time Data Error

249

TIM

Time Not Set

249

HOA

Keypad

Display

Name

Page

UL3

Undertorque Detection 1

249

UL5

Mechanical Weakening Detection 2

250

Uv1

<3>

Control Circuit Undervoltage Fault

250

Uv2

<3>

Control Power Supply Voltage Fault

250

Uv3

<3>

Undervoltage 3 (Soft-Charge Bypass Circuit

Fault)

250

<1> Displayed as CPF00 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show

CPF01.

<2> Displayed as CPF20 when occurring at drive power up. When one of the faults occurs after successfully starting the drive, the display will show

CPF21.

<3> Fault histories are not kept when CPF00, CPF01, CPF06, CPF24, Fdv, oFA00, oFb00, oFC00, Uv1, Uv2, or Uv3 occur.

n

Minor Faults and Alarms

Refer to

Table 6.5

for an overview of possible alarm codes. Conditions such as overvoltages can trip faults and alarms. It is

important to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects an alarm, the ALM indicator LED blinks and the alarm code display flashes. Most alarms trigger a

digital output programmed for alarm output (H2-oo = 10). A fault (not an alarm) is present if the ALM LED lights without

blinking.

Refer to Faults on page 232

for information on fault codes.

Table 6.5 Minor Fault and Alarm Displays

HOA

Keypad

Display

Name

Minor Fault

Output

(H2-oo = 10)

Page

AEr

Station Address Setting Error (CC-

Link, CANopen, MECHATROLINK)

YES

251

AL02

BAS Interlock Open

251

AL03

Smoke Purge in Bypass

251

AL04

Smoke Purge in Drive

251

AL13

Loss of Load

251

AL14

Serial Communications Alarm

251

AL16

Input Phase Rotation

252

AUv

Power Supply Undervoltage

YES

235

bb

Baseblock

No output

<2>

252

bUS

Option Card Communications Error

YES

252

CALL

Serial Communication Transmission

Error

YES

253

CE

MEMOBUS/Modbus Communication

Error

YES

253

CrST

Cannot Reset

YES

253

dnE

Drive Disabled

YES

253

doH

Damping Resistor Overheat

236

EF

Forward/Reverse Run Command

Input Error

YES

254

EF0

Option Card External Fault

YES

254

EF1 to

EF8

External Fault

(input terminal S1 to S8)

YES

254

FbH

Excessive PID Feedback

YES

254

FbL

PID Feedback Loss

YES

255

HOA

Keypad

Display

Name

Minor Fault

Output

(H2-oo = 10)

Page

Fdv

Power Supply Frequency Fault

241

HCA

Current Alarm

YES

255

inTLK

Interlock Open

255

LT-1

Cooling Fan Maintenance Time

No output

<1>

255

LT-2

Capacitor Maintenance Time

No output

<1>

256

LT-3

Soft Charge Bypass Relay

Maintenance Time

No output

<1>

256

oH

Heatsink Overheat

YES

256

oH2

Heatsink Overheat Warning

YES

256

oH3

Motor Overheat

YES

256

oL3

Overtorque 1

YES

257

ov

Control Circuit Overvoltage

YES

257

PASS

MEMOBUS/Modbus Test Mode

Complete

No output

257

SAFE

Customer Safety

257

SE

MEMOBUS/Modbus Test Mode Fault

YES

257

SoH

Snubber Discharge Resistor Overheat

YES

248

SrC

Phase Order Detection Fault

248

UL3

Undertorque Detection 1

YES

258

Uv1

Control Circuit Undervoltge

YES

258

WrUn

Waiting for Run

YES

258

<1> Output when H2-oo = 2F.

6.3 Drive Alarms, Faults, and Errors

YASKAWA SIEP YAIZ1D 01A Z1000U HVAC MATRIX Drive Bypass Technical Manual

233

6

Diagnostics & Troubleshooting

Advertising