No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

H3-08

(0416)

Terminal A3 Bias

Setting

Terminal A3 Bias

Sets the level of the input value selected in H3-06 when 0 V is

input at terminal A3.

Default: 0.0%

Min.: -999.9

Max.: 999.9

176

H3-09

(0417)

Terminal A2 Signal

Level Selection

Term A2 Level

0: 0-10V,

(LowLim=0)

1: 0-10V, (BipolRef)

2: 4-20 mA

3: 0-20 mA

0: 0 to 10 V with zero limit

1: 0 to 10 V without zero limit

2: 4 to 20 mA

3: 0 to 20 mA

Note:

Use jumper switch S1 to set input terminal A2

for current or voltage input signal.

Default: 2

Range: 0 to 3

176

H3-10

(0418)

Terminal A2 Function

Selection

Term A2 FuncSel

Sets the function of terminal A2.

Default:

<1>

Range: 0 to 26

177

H3-11

(0419)

Terminal A2 Gain

Setting

Terminal A2 Gain

Sets the level of the input value selected in H3-10 when 10 V

(20 mA) is input at terminal A2.

Default: 100.0%

Min.: -999.9

Max.: 999.9

177

H3-12

(041A) Terminal A2 Bias

Setting

Terminal A2 Bias

Sets the level of the input value selected in H3-10 when 0 V (0

or 4 mA) is input at terminal A2.

Default: 0.0%

Min.: -999.9

Max.: 999.9

177

H3-13

(041B)

Analog Input Filter Time

Constant

A1/A2 Filter T

Sets a primary delay filter time constant for terminals A1 and

A2. Used for noise filtering.

Default: 0.03 s

Min.: 0.00

Max.: 2.00

177

H3-14

(041C)

Analog Input Terminal

Enable Selection

A1/A2/A3 Sel

1: A1 Available

2: A2 Available

3: A1/A2 Available

4: A3 Available

5: A1/A3 Available

6: A2/A3 Available

7: All Available

Determines which analog input terminals will be enabled or

disabled when a digital input programmed for “Analog input

enable” (H1-oo = C) is activated.

The terminals not set as the target are not influenced by input

signals.

1: Terminal A1 only

2: Terminal A2 only

3: Terminals A1 and A2 only

4: Terminal A3 only

5: Terminals A1 and A3

6: Terminals A2 and A3

7: All terminals enabled

Default: 7

Range: 1 to 7

177

H3-16

(02F0)

Terminal A1 Offset

TerminalA1Offset

Adds an offset when the analog signal to terminal A1 is at 0 V. Default: 0

Min.: -500

Max.: 500

178

H3-17

(02F1)

Terminal A2 Offset

TerminalA2Offset

Adds an offset when the analog signal to terminal A2 is at 0 V. Default: 0

Min.: -500

Max.: 500

178

H3-18

(02F2)

Terminal A3 Offset

TerminalA3Offset

Adds an offset when the analog signal to terminal A3 is at 0 V.

Default: 0

Min.: -500

Max.: 500

178

<1> Default is 0 when b5-01 is set to 0.

Default is B when b5-01 is set to 1 or 3.

H3 Multi-Function Analog Input Settings

H3-oo

Setting

Function

LCD Display

Description

Page

0

Frequency bias

Freq Ref Bias

10 V = E1-04 (maximum output frequency)

178

1

Frequency gain

Freq Ref Gain

0 to 10 V signal allows a setting of 0 to 100%. -10 to 0 V signal allows a setting

of -100 to 0%.

178

2

Auxiliary frequency

reference 1

(used as a Multi-Step

Speed 2)

Aux Reference1

10 V = E1-04 (maximum output frequency)

178

3

Auxiliary frequency

reference 2

(3rd step analog)

Aux Reference2

10 V = E1-04 (maximum output frequency)

178

4

Output voltage bias

Voltage Bias

10 V = E1-05 (motor rated voltage)

178

5

Accel/decel time gain

Acc/DecTime Gain

10 V = 100%

179

B.8 H Parameters: Multi-Function Terminals

YASKAWA SIEP YAIZ1D 01A Z1000U HVAC MATRIX Drive Bypass Technical Manual

327

B

Parameter List