B.10 n: Special Adjustment

The n parameters adjust more advanced performance characteristics such as Hunting Prevention, speed feedback detection,

High Slip Braking, and Online Tuning for motor line-to-line resistance.

u

n1: Hunting Prevention

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

n1-01

(0580)

Hunting Prevention

Selection

Hunt Prev Select

0: Disabled

1: Enabled

0: Disabled

1: Enabled

Default: 1

Range: 0, 1

194

n1-02

(0581)

Hunting Prevention

Gain Setting

Hunt Prev Gain

If the motor vibrates while lightly loaded, increase the gain by

0.1 until vibration ceases. If the motor stalls, decrease the gain

by 0.1 until the stalling ceases.

Default: 1.00

Min.: 0.00

Max.: 2.50

194

u

n3: Overexcitation Braking

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

n3-13

(0531)

Overexcitation

Deceleration Gain

Hflux Brake Gain

Sets the gain applied to the V/f pattern during Overexcitation

Deceleration (L3-04 = 4).

Default: 1.10

Min.: 1.00

Max.: 2.00

194

B.10 n: Special Adjustment

334

YASKAWA SIEP YAIZ1D 01A Z1000U HVAC MATRIX Drive Bypass Technical Manual