5. Commissioning

5-35

Festo P.BE-MTR-DCI-PB-EN en 1209a

5.5.5 Response monitoring

The response monitoring influences the reaction when field-
bus communication fails, e.g. due to cable fracture. The MTR-
DCI can be operated with active or inactive response monitor-
ing.

With active response monitoring, the drive is stopped with
the emergency stop ramp after the response monitoring time
has expired, and then remains stationary in a controlled posi-
tion.

With inactive response monitoring, the current drive function
is still carried out if fieldbus communication fails.

5.5.6 Control commands

FREEZE, SYNC and CLEAR_DATA are supported by the MTR-
DCI in accordance with EN 50170.

The method of accessing these commands depends on the
controller used. Please refer to the documentation for your
control system.