Festo Электромотор MTR-DCI User Manual

Page 47

Advertising
background image

2. Mounting

2-7

Festo P.BE-MTR-DCI-PB-EN en 1209a

Note
Motor unit MTR-DCI-62-...-G22 can generate torque peaks
of up to 37 Nm at a peak current of 20 A in the start-up
phase.

Make sure by calculating the dynamic loading that
the maximum safe shaft output torque for the gear is
not exceeded even in the start-up phase (e.g. by reduc-
ing the load).

Use the thread on the front of the gear (see Fig. 2/2) when
mounting the MTR-DCI to a mechanical drive fixture (machine
frame).

In order to minimise the shaft offset: position the axis with
the aid of the centring diameter (D1 or D3, see Tab. 2/1)
relative to the rotary axis of the mechanism to be driven.

Fasten the motor unit with 4 screws and tighten the
4 screws with the specified tightening torque.

Motor unit type MTR-DCI-32 has a total of 6 threads for
different motor mounting variants (axial, parallel). In each
case, only 4 screws must be used.

Size

Thread /
thread depth

Tightening torque

MTR-DCI-32-...

M3

6 mm

1.2 Nm

MTR-DCI-42-...

M3

7 mm

1.2 Nm

M4

10 mm

2.9 Nm

MTR-DCI-52-...

M5

10 mm

5.9 Nm

MTR-DCI-62-...

M5

10 mm

5.9 Nm

Tab. 2/3: Tightening torques

Advertising