Description of the general status bytes – Festo Электромотор MTR-DCI User Manual

Page 134

Advertising
background image

5. Commissioning

5-46

Festo P.BE-MTR-DCI-PB-EN en 1209a

Description of the general status bytes

Status byte 1 (SCON)

Bit

EN

Description

B0
ENABLED

Drive

Enabled

= 0: Drive blocked, controller not active
= 1: Drive (controller) enabled

B1
OPEN

Operation
Enabled

= 0: Stop active
= 1: Operation enabled, positioning possible

B2
WARN

Warning

= 0: Warning not active
= 1: Warning active

B3
FAULT

Fault

= 0: No fault
= 1: There is an active fault, or reaction to fault is active.

Fault number in diagnostic memory

B4
24VL

Supply Voltage is Applied

= 0: No load voltage
= 1: Load voltage applied

B5
LOCK

Drive control by FCT/HMI

= 0: Device control by PLC/fieldbus
= 1: Device control by FCT/HMI

(PLC control is

locked)

B6
OPM1

Display
Operating Mode

= 00: Record Select (Standard)
= 01: Direct mode
= 10: Reserved
= 11: Reserved

B7
OPM2