B. Supplementary information

B-74

Festo P.BE-MTR-DCI-PB-EN en 1209a

Version FCT PlugIn Min.

CI access

2067h

00h

Var

V-string

r

Description

Minimum version of the MTR-DCI FCT plugin required for commissioning the
MTR-DCI. Format = “xx.yy” (xx = main version, yy = secondary version).

Version FCT PlugIn Opt.

CI access

2068h

00h

Var

V-string

r

Description

Optimum version of the MTR-DCI FCT plugin for commissioning the MTR-DCI.
Format = “xx.yy” (xx = main version, yy = secondary version).

Scaling (control panel settings)

CI access

20D0h

01h, 02h

Array

uint8

rw/r

Description

Definition of the units of measurement used on the control panel and the num-
ber of decimal places. See also CI object 20FFh/PNU 126.

Measuring Unit 20D0h

01h

uint8

rw

Defines the unit of measurement (

Z 20FF03h).

The setting for the system of measurement units only affects the display
readout. All parameters are always saved in increments in the controller and
are not converted into the relevant measuring system until they are written or
read.
Values:
1 (0x01): Metric units of measurement:

e. g. mm, mm/s, mm/s

2

4 (0x04): Angular units of measurement (360°), e.g. degrees, degrees/s, de-
grees/s

2

8 (0x08): Revolutions: rev, rev/min, rev/min

2

15 (0x0F): Increments

Scaling Size 20D0h

02h

uint8

r

Number of places after the decimal point. Fixed: 2. (

Z 20FF04h).