5. Commissioning

5-53

Festo P.BE-MTR-DCI-PB-EN en 1209a

3. Fault handling

Step/
Description

Control bytes

Status bytes

Byte

B7

B6

B5 B4

B3 B2 B1

B0

Byte

B7 B6 B5 B4 B3 B2 B1 B0

3.1 Fault

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP

ENABL

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

CCON x

x

x

x

x

x

x

x

SCON x

x

x

x

1

x

x

x

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HALT

CPOS x

x

x

x

x

x

x

x

SPOS x

x

x

x

x

0

x

x

3.2 Warning

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP

ENABL

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

CCON x

x

x

x

x

x

x

x

SCON x

x

x

x

x

1

x

x

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HALT

CPOS x

x

x

x

x

x

x

x

SPOS x

x

x

x

x

0

x

x

3.3 Reset fault

with CCON.B3
(RESET)

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP

ENABL

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

CCON 0

x

x

x

F

x

x

1

SCON 0

x

0

1

0

0

0

0

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HALT

CPOS x

0

0

0

0

0

x

x

SPOS x

0

0

0

0

1

0

1

3.4 Reset fault

with CCON.B0
(ENABLE)

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP

ENABL

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

CCON 0

x

x

x

0

x

x

N

SCON 0

x

0

1

0

0

x

0

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HALT

CPOS x

0

0

0

0

0

x

x

SPOS x

0

0

0

0

1

x

x

0: 0-signal;

1: 1-signal;

x: not relevant (any);

F: Edge positive

Tab. 5/11: Control and status bytes for “Fault handling”

Advertising