Festo Электромотор MTR-DCI User Manual

Page 56

Advertising
background image

3. Installation

3-8

Festo P.BE-MTR-DCI-PB-EN en 1209a

Load voltage

The power electronics and thereby the motor are supplied
with DC voltage via the power supply connection.
} section 3.3.2

Logic voltage

The logic components are either also supplied via the power
supply connection (except for MTR-DCI-32), or are supplied
separately from the load voltage via the fieldbus adapter
FBA-...

} Section 3.3.3

The permitted voltages and currents can be found in appen-
dix A.1.

Recommendation
For the load voltage supply, use a stabilised power supply
unit with high reserve capacity and external fuses.

Power supply units and fuses:

MTR-…-32

MTR-…-42

MTR-…-52

MTR-…-62

Recommended
power unit
(stabilised)

DC 24 V /3 A

DC 24 V / 6 A

DC 24 V/ 10 A

DC 48 V / 20 A

External fuse,
secondary

5 A slow-blowing

7 A slow-blowing

10 A slow-blowing 25 A slow-blowing

Tab. 3/3: Power supply units (for load voltage) and fuses

Advertising