Festo Электромотор MTR-DCI User Manual

Page 257

Advertising
background image

B. Supplementary information

B-51

Festo P.BE-MTR-DCI-PB-EN en 1209a

Drive Data

PNU

1026

1...8

0...7

uint32

rw

Description

General drive data

Output stage temp.

(output stage

temp.)

1026

1 (CI: 01h)

0

uint32

rw

Temperature of the output stage in °C. Range of values: 0 ... 85

Output stage

max. temp.

(output stage max.

temp)

1026

2 (CI: 02h)

1

uint32

rw

Maximum temperature of the output stage in °C. Fix: 80 (0x0050)

Motor nominal

current

(motor nominal

current)

1026

3 (CI: 03h)

2

uint32

rw

Motor nominal current in [mA]
Value is automatically entered when an axis type is selected (PNU 1005/4).

Current limit

(max. motor

current)

1026

4 (CI: 04h)

2

uint32

rw

Max. motor current in per mill of nominal current. Identical to PNU 1034.
Range of values: 1...2000

Lower current limit

(min. motor

current)

1026

5 (CI: 05h)

4

uint32

rw

= PNU1026.4 * (-1)

Device control

(device

control)

1026

6 (CI: 06h)

5

uint32

rw

Setting the device control (refer to PNU 125 / object 207Dh).
0: Control via HMI (control panel) or FCT, no control via fieldbus
1: Control via fieldbus – control interface (default)

Controller serial

number

(controller serial

number)

1026

7 (CI: 07h)

6

uint32

rw

Serial number of the controller in format 0xDDMYYSSS:
DD (Day):

8 bits:

0x01...0x1F

M (month):

4 bits:

0x1...0xC

YY (Year):

8 bits:

0x00...0x63

SSS (serial no.):

12 bits:

0x001...0xFFF

Following error

(permissible

following error)

1026

8 (CI: 08h)

7

uint32

rw

Following error monitoring

Advertising