5. Commissioning

5-42

Festo P.BE-MTR-DCI-PB-EN en 1209a

Description of the general control bytes

Control byte 1 (CCON)

Bit

EN

Description

B0
ENABLE

Enable drive

= 1: Drive (controller) enabled
= 0: Drive (controller) blocked

B1
STOP

Stop

= 1: Operation enabled.

Any faults will be deleted.

= 0: Stop 1 active (emergency ramp + cancel positioning

task). The axis stops with maximum braking ramp; the
positioning task is reset.

B2
BRAKE

Reserved, must be at 0

B3
RESET

Reset fault

An active fault is acknowledged/reset and the fault number
is deleted by means of a rising edge.

B4

Reserved, must be at 0

B5
LOCK

HMI access

locked

Controls access to the diagnostic interface:
= 1: HMI and FCT may only observe the drive, the device

control (HMI control) cannot be taken over by HMI and
FCT.

= 0: HMI or FCT may take over control of the device (in order

to modify parameters or to control inputs)

B6
OPM1

Select

Operating Mode

= 00:

Record Select

= 01:

Direct mode

= 10:

Reserved

= 11:

Reserved

B7
OPM2

Control byte 1 (CCON) is used to control all states which must
be available in all operation modes. The cooperation of the
control bits can be found under the description of the drive
functions in section 5.8.