Position Control Parameter Set

PNU

1024

18...23, 32

d

17...22, 31

d

uint16

rw

Description

Control parameters.
Modification is only permitted for servicing purposes.
If necessary consult Festo.

Gain Position 1024

18

d

(CI: 12h)

17

d

Gain for position controller.
Value range: MTR-DCI-32: 1...100; MTR-DCI-42/52/62: 1...200
Default: MTR-DCI-32: 20; MTR-DCI-42: 15; MTR-DCI-52: 10; MTR-DCI-62: 8

Gain Velocity 1024

19

d

(CI:13h)

18

d

Gain for speed controller.
Value range: MTR-DCI-32: 1...3000; MTR-DCI-42/52/62: 1...700
Default: MTR-DCI-32: 2800; MTR-DCI-42/52: 600; MTR-DCI-62: 500

I-Fraction Velocity 1024

20

d

(CI:14h)

19

d

Integral term for speed controller.
Value range: 1...600
Default: MTR-DCI-32: 80; MTR-DCI-42/52/62: 340

Gain Current 1024

21

d

(CI:15h)

20

d

Gain for current controller.
Value range: MTR-DCI-32: 1...1000; MTR-DCI-42/52/62: 1...800
Default: MTR-DCI-32: 110; MTR-DCI-42/52/62: 150

I-Fraction 1024

22

d

(CI:16h)

21

d

Integral term for current regulator.
Value range: MTR-DCI-32/42/52: 0...1000
Default: MTR-DCI-32: 90; MTR-DCI-42: 420; MTR-DCI-52: 350

Gain Velocity

Trajectory

1024

23

d

(CI:17h)

22

d

Gain for speed controller – trajectory generator.
Value range: 1...2
Default: 1

Save Position 1024

32

d

(CI:20h)

31

d

Saves current position in the EEPROM when power is switched off.
Fixed = 240 (0x00F0): current position is

not saved at Power-Off.

CI access

60FBh

12h...17h, 20h

uint16

rw