4. The control panel (type MTR-DCI-...-H2)

4-7

Festo P.BE-MTR-DCI-PB-EN en 1209a

Menu command

Description

}

Diagnostic

Displays the system data and the currently effective settings
(see section 4.3)

} Pos. set table

Displays the position set table

} Axis parameter

Displays axis parameters and data

} System paramet

Displays system parameters and system data

} PROFIBUS Diag

Displays PROFIBUS diagnosis data

} SW information

Displays the operating system version (firmware)

}

Positioning

1) 2)

Homing and positioning runs for testing the position set records (see section 4.5)

} Move posit set

Starts the positioning run for “position set record”

} Demo posit tab

Starts the positioning run for “position set table”

} Homing

Starts the homing run

}

Settings

1) 2)

Selection of the drive, parameter assignment, programming the position set records...
(see section 4.4)

} Axis type

} Type DMES-...

Valve actuator DMES-...

} Type DNCE-...

Electric cylinder DNCE-...

} Rotation drive

Rotational axis with stop

} User config

Any linear drive

} Axis parameter

} Zero point

3)

Offset of axis zero point

} Abs.min.pos

3)

Stroke limitation: software end position, negative

} Abs.max.pos

3)

Stroke limitation: software end position, positive

} Save...

Saves parameters in EEPROM

} Homing

paramet

} Homing method

Selection of reference travel method (stop, software limit switch...)

} Velocity v_sw

Positioning speed for searching for the homing point

} Velocity v_s0

Positioning speed for moving to the axis zero point

} Save...

Saves parameters in EEPROM

} Position set

} Position nr.

Number of the position set record (0...31)

} Pos set mode

Absolute or relative positioning

} Position

3)

Target position of the position set record

} Velocity

Positioning speed of the position set record

} Save...

Saves parameters in EEPROM

} Password edit

Sets up a local password with 3 digits for the control panel (see section 4.4).

} PB Parameter

Sets the PROFIBUS address

}

HMI control

1)

Presetting for device control via the control panel (see section 4.6)

}

LCD adjustment

Rotates the display in steps of 90°

1)

May be password-protected

3)

Teach mode

2)

Control interface must be deactivated; see [HMI control] :HMI = on

Tab. 4/3: Menu commands (overview)