B.1.6 layout of the parameter entries – Festo Электромотор MTR-DCI User Manual

Page 226

Advertising
background image

B. Supplementary information

B-20

Festo P.BE-MTR-DCI-PB-EN en 1209a

B.1.6

Layout of the parameter entries

Encoder Resolution

PNU

1001

1...2

0...1

uint32

rw

Description

Encoder resolution in increments / revolutions
The encoder resolution is fixed and cannot be modified by the user.
The calculated value is derived from the fraction (encoder increments/
motor revolutions).

Encoder Increments

1001

1

0

Value range: 0 ... 2

32

-1

Default: 500

Motor Revolutions

1001

2

1

Fixed = 1

CI access

608Fh

01h...02h

uint32

rw

1

Name of the parameter (sometimes with explanation in brackets)

2

Parameter number (PNU)

3

Subindices of the parameter for FHPP with DPV0
– :

The object has no subindex (simple variable)

1...30:

The object has subindices from 1..30

4

Subindices of the parameter for FHPP with DPV1

5

Variable type of element. If there is a subindex, the parameter is an “array”;
“records” are not used

6

Description of the parameter

7

If applicable: explanation of the subindices

8

Read/write permission: ro = read only

wo = write only
rw = read and write

9

Corresponding CI object (see section B.2)

Fig. B/1: Layout of the parameter entries

1

2

3

4

5

6

7

8

9

Advertising