B. Supplementary information

B-58

Festo P.BE-MTR-DCI-PB-EN en 1209a

Permitted value ranges

Transferred parameters and values are checked by the
MTR-DCI before being accepted.

Note
In the case of invalid parameters or values, an error mess-
age will not appear in the response; rather, the received
value will always be returned.

Invalid parameters will not be accepted.

Values outside the permitted value range will be limited
to the nearest valid value.

Recommendation:
Check that values and parameters have been written correctly
by downloading the current contents of the parameter or
value with one of the following Read commands:

Error messages

If errors are made in commands (syntax faults), the value
<0xFF> will be transmitted instead of the usual response.

Possible causes:

Incorrect initial character, separating character or empty
character

Incorrect hex digit

Incorrect value type