5. Commissioning

5-44

Festo P.BE-MTR-DCI-PB-EN en 1209a

Description of the special control bytes
– Direct mode

Control byte 3 (CDIR) – Direct mode

Bit

EN

Description

B0
ABS

Absolute/ Relative

= 0: Nominal value is absolute
= 1: Nominal value is relative to last nominal value

B1
COM1

Control Mode

= 00: Position control
= 01: Force mode
= 10: Reserved
= 11: Reserved

B2
COM2

B3
CONT

Reserved, must be at 0

B4
VLIM

Reserved, must be at 0

B5
XLIM

Stroke (

X-) limit not active

Force mode
= 0: Stroke monitoring active
= 1: Stroke monitoring not active

B6
FAST

Reserved, must be at 0

B7
FUNC

Reserved, must be at 0

Control byte 4 (nominal value 1) – Direct mode

Bit

EN

Description

B0 ... B7

Velocity

Preselection of velocity in % of the maximum velocity

Control bytes 5... 8 (nominal value 2) – Direct mode

Bit

EN

Description

B0...B31

Position, force, ...

Preselection of the position in increments or of the
force in % of nominal current