Record Target Position

PNU

404

1...32

d

0...31

d

int32

rw

Description

Target position of the position set table. Position nominal value as per PNU 401 /
RCB1 absolute or relative, in increments. Default: 0
Value range: -2

31

...+(2

31

-1) (0x80000000 ... 0x7FFFFFFF)

Record 0 404

1

0

Nominal position value for position set record 0 (homing)

Record ... 404

...

...

Nominal position value for position set record 1 ... 30

Record 31 404

32

31

Nominal position value for position set record 31

CI access

20ECh

01h ... 20h

int32

rw

Note: the CI object 20E0h/02h is intended for access via CI.

Record Velocity

PNU

406

1...32

d

0 ... 31

d

uint32

rw

Description

Nominal speed value in increments/s. Default: 0.
Value range: MTR-DCI-32: 0...66000. MTR-DCI-42/52: 0...100000.
MTR-DCI-62: 0...113400

Record 0 406

1

0

Nominal speed value for position set record 0 (homing)

Record ... 406

...

...

Nominal speed value for position set record 1 ... 30

Record 31 406

32

31

Nominal speed value for position set record 31

CI access

20EDh

01h ... 20h

uint32

rw

Note: the CI object 20E0h/03h is intended for access via CI.