} Settings

Axis type

Type DMES...

Type DNCE...

Rotation drive

User config

5. Commissioning

5-8

Festo P.BE-MTR-DCI-PB-EN en 1209a

5.2.1

Selecting the axis type

1. Select your axis type:

Festo positioning axis [Type DMES-...]

Festo electrical drive [Type DNCE-...]

Any axis of rotation [Rotation drive]

Any linear axis [User config]

2. Set axis-specific parameters as prompted using the arrow

buttons, e.g. feed constant, system of measurement,
or counting direction.

Axis type

Parameters

Type DMES

A DMES size can be selected, according to the size of the MTR-DCI. The feed
constant is already configured.

Type DNCE

FeedCon: feed constant in [mm/rev]
(see documentation for your DNCE).

Count direction: active direction (direction of motor rotation), left or right
(see 1.5).

Rotation drive

1)

Any rotary/semi-rotary drive:

[Degrees] (360°/rev) or

[Revolutions]

User config

Any linear drive: Feed constant in [mm/rev] as per the documentation of your
linear axis.

1) If an external gear is used, the gear factor can be set with FCT.

Tab. 5/2: Assigning parameters to the axis

3. Save the settings with