Festo Электромотор MTR-DCI User Manual

Page 53

Advertising
background image

3. Installation

3-5

Festo P.BE-MTR-DCI-PB-EN en 1209a

The plug connectors on the Festo cables listed in the follow-
ing are of protection class IP54.

Connection

Cable

Designation

Length [m]

Parameterisation

Programming cable

KDI-MC-M8-SUB-9-2.5

2.5 (max. 2.5)

Reference switch

Connecting cable

KM8-M8-GSGD-...

0.5 / 1 / 2 / 5

Power supply

Power supply cable

KPWR-MC-1-SUB-9HC-...

2.5 / 5 / 10
(max. 10)

PLC controller

Fieldbus adapter FBA-...
for connecting the fieldbus
cable

FBA-PB-SUB-9-3XM12

–

Tab. 3/2: Overview of cables (accessories)

To maintain the IP protection class:

•

Seal unused M8 terminals with ISK-M8 protective caps
(accessories)

•

Tighten the union nuts/locking screws on the plugs by
hand (torques: see documentation for cables and plugs).

Caution
Long lines reduce immunity to interference (EMC).

•

Do not exceed the specified maximum cable lengths.

Note

•

Lay all moveable motor and sensor cables free of bends
and free of mechanical stress, in a drag chain if ne-
cessary.

Advertising