Festo Электромотор MTR-DCI User Manual
Page 53

3. Installation
3-5
Festo P.BE-MTR-DCI-PB-EN en 1209a
The plug connectors on the Festo cables listed in the follow-
ing are of protection class IP54.
Connection
Cable
Designation
Length [m]
Parameterisation
Programming cable
KDI-MC-M8-SUB-9-2.5
2.5 (max. 2.5)
Reference switch
Connecting cable
KM8-M8-GSGD-...
0.5 / 1 / 2 / 5
Power supply
Power supply cable
KPWR-MC-1-SUB-9HC-...
2.5 / 5 / 10
(max. 10)
PLC controller
Fieldbus adapter FBA-...
for connecting the fieldbus
cable
FBA-PB-SUB-9-3XM12
–
Tab. 3/2: Overview of cables (accessories)
To maintain the IP protection class:
•
Seal unused M8 terminals with ISK-M8 protective caps
(accessories)
•
Tighten the union nuts/locking screws on the plugs by
hand (torques: see documentation for cables and plugs).
Caution
Long lines reduce immunity to interference (EMC).
•
Do not exceed the specified maximum cable lengths.
Note
•
Lay all moveable motor and sensor cables free of bends
and free of mechanical stress, in a drag chain if ne-
cessary.