Festo Электромотор MTR-DCI User Manual

Page 233

Advertising
background image

B. Supplementary information

B-27

Festo P.BE-MTR-DCI-PB-EN en 1209a

Diagnostic Memory Parameter (diagnostic memory parameters)

PNU

204

1...4

0...3

uint8

rw

Description

Configuration of the diagnostic memory.

Fault Type 204

1

0

Incoming and outgoing faults
1 (0x01): Record incoming and outgoing

*)

faults (default)

2 (0x02): Record only incoming faults
*) Outgoing fault = time when the fault was acknowledged (= reset).

Resolution 204

2

1

1 (0x01): Time stamp resolution 10 ms (default)
2 (0x02): Time stamp resolution 1 ms

Clear Memory 204

3

2

Deletes diagnostic memory by writing value = 1.
Read will always be answered with value = 1.

Number of Entries 204

4

3

Reads out the number of entries in the diagnostic memory.

CI access

20CCh

01h...04h

uint8

rw/ro

Device Error (device fault)

PNU

205

uint16

rw

Description

Reading or deleting the active device fault.
Read [bit 0...15]: see section 6.3, Tab. 6/7.
Write 0 (0x0000): deletes all faults.

CI access

2FF1h

00h

uint16

rw

Advertising