Festo Электромотор MTR-DCI User Manual
Page 157

5. Commissioning
5-69
Festo P.BE-MTR-DCI-PB-EN en 1209a
3. Teaching takes place via the handshake of the bits in the
control and status bytes CPOS/SPOS:
1
Ready for teaching
2
Value transferred
1
0
Acknow-
ledgment
SPOS.B3
Teaching value
CPOS.B5
1
2
1
0
Fig. 5/6:
Handshake when teaching
Note:
The drive does not need to stop moving for teaching. How-
ever, a speed of 1 m/s means that the actual position
changes by 1 mm every millisecond. With the usual cycle
times of PLC + fieldbus + motor controller, there will still be
inaccuracies of several millimetres even at a speed of only
100 mm/s.
Overview of parameters involved (see sections B.1.10 and B.1.11)
Parameters involved
Description
FCT
PNU
CI
Teach target
–
1)
520
21FCh
Set number
–
1)
400
2033h
Start
CPOS.B5 = Falling edge: Teach value
Feedback signal
SPOS.B3 = 1: Value transferred
Requirement
Device control by PLC/fieldbus
Controller must be in status “Operation enabled”
1)
Teach function is made possible in the Festo Configuration Tool by special functions.
Tab. 5/22: Parameters involved for teaching