Festo Электромотор MTR-DCI User Manual

Page 157

Advertising
background image

5. Commissioning

5-69

Festo P.BE-MTR-DCI-PB-EN en 1209a

3. Teaching takes place via the handshake of the bits in the

control and status bytes CPOS/SPOS:

1

Ready for teaching

2

Value transferred

1

0

Acknow-
ledgment
SPOS.B3

Teaching value
CPOS.B5

1

2

1

0

Fig. 5/6:

Handshake when teaching

Note:
The drive does not need to stop moving for teaching. How-
ever, a speed of 1 m/s means that the actual position
changes by 1 mm every millisecond. With the usual cycle
times of PLC + fieldbus + motor controller, there will still be
inaccuracies of several millimetres even at a speed of only
100 mm/s.

Overview of parameters involved (see sections B.1.10 and B.1.11)

Parameters involved

Description

FCT

PNU

CI

Teach target

1)

520

21FCh

Set number

1)

400

2033h

Start

CPOS.B5 = Falling edge: Teach value

Feedback signal

SPOS.B3 = 1: Value transferred

Requirement

Device control by PLC/fieldbus
Controller must be in status “Operation enabled”

1)

Teach function is made possible in the Festo Configuration Tool by special functions.

Tab. 5/22: Parameters involved for teaching