2 composition of the cyclical i/o data – Festo Электромотор MTR-DCI User Manual

Page 127

Advertising
background image

5. Commissioning

5-39

Festo P.BE-MTR-DCI-PB-EN en 1209a

5.7.2

Composition of the cyclical I/O data

Concept

A master exchanges the following data with the FHPP:

Control and status bytes

Record number or nominal position in the output data

Feedback of actual position and record number in the
input data

Additional mode-dependent nominal and actual values

Parameters as per FPC

The FHPP protocol always provides 8 input bytes and 8 out-
put bytes for this. The first 2 of these bytes are fixed. They are
retained in each operation mode, and control the enabling of
the MTR-DCI and the operation modes. Bytes 3 to 8 depend
on the operation mode selected. Further control or status
bytes and nominal and actual values can be transferred here.

In the cyclical data a further 8 input bytes and 8 output bytes
are permitted for transferring parameters in accordance with
the FPC protocol.

The acyclical data channel of the PROFIBUS (DPV1) is also
supported.