2 composition of the cyclical i/o data – Festo Электромотор MTR-DCI User Manual
Page 127
![background image](/manuals/464458/127/background.png)
5. Commissioning
5-39
Festo P.BE-MTR-DCI-PB-EN en 1209a
5.7.2
Composition of the cyclical I/O data
Concept
A master exchanges the following data with the FHPP:
–
Control and status bytes
–
Record number or nominal position in the output data
–
Feedback of actual position and record number in the
input data
–
Additional mode-dependent nominal and actual values
–
Parameters as per FPC
The FHPP protocol always provides 8 input bytes and 8 out-
put bytes for this. The first 2 of these bytes are fixed. They are
retained in each operation mode, and control the enabling of
the MTR-DCI and the operation modes. Bytes 3 to 8 depend
on the operation mode selected. Further control or status
bytes and nominal and actual values can be transferred here.
In the cyclical data a further 8 input bytes and 8 output bytes
are permitted for transferring parameters in accordance with
the FPC protocol.
The acyclical data channel of the PROFIBUS (DPV1) is also
supported.