5. Commissioning

5-51

Festo P.BE-MTR-DCI-PB-EN en 1209a

1. Establishing “ready to operate” status –
Record Select

Step/
Description

Control bytes

Status bytes

Byte

B7

B6

B5 B4

B3 B2 B1

B0

Byte

B7 B6 B5 B4 B3 B2 B1 B0

1.1 Basic status

(HMI device control =
off )

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP

ENABL

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

CCON 0

0

0

0

0

x

0

0

SCON 0

0

0

1

0

0

0

0

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HALT

CPOS x

0

0

0

0

0

0

0

SPOS 0

0

0

0

0

1

0

0

1.2 Disable device
control by FCT/HMI
(optional)

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP

ENABL

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

CCON x

x

1

x

x

x

x

x

SCON x

x

0

x

x

x

x

x

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HALT

CPOS x

x

x

x

x

x

x

x

SPOS x

x

x

x

x

x

x

x

1.3 Enable drive, en-
able operation

(Record Select)

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP

ENABL

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

CCON

0

0

x

x

0

x

1

1

SCON

0

0

0

1

0

0

1

1

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HALT

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HALT

CPOS x

0

0

0

0

0

0

1

SPOS 0

0

0

0

0

1

0

1

0: 0-signal;

1: 1-signal;

x: not relevant (any);

F: Edge positive

Tab. 5/9: Control and status bytes for “Establishing 'ready to operate' status –

Record Select”

Description for 1. Establishing “ready to operate” status:

1.1

Basic status of the drive when the supply voltage is
switched on.
} Step 1.2 or 1.3

1.2

Disable device control by FCT/HMI (optional).
Takeover of device control by FCT/HMI can be disabled
with CCON.B5 = 1 (LOCK).
} Step 1.3

1.3

Enable drive in Record Select mode.

} Homing: example 4, Tab. 5/12.

If there are faults after switching on or after setting CCON.B0
(ENABLE):
} Fault handling: see example 3, Tab. 5/11.

Advertising