Parameters involved (Record Select)

The entries in the position set table can be written via the
fieldbus (PNU 401...407).

The composition of the position set table as per FHPP is
described in appendix B.1.10.

Overview of parameters involved (see section B.1.10)

Parameters involved

Description

FCT

PNU

CI

Absolute/relative positioning

x

401

20E0/01h

Target position

x

404

20E0/02h

Velocity

x

406

20E0/03h

Acceleration / deceleration

x

407

20E0/04h

Start

CPOS.B1 = positive edge: Start
Jogging and homing have priority.

Feedback

SPOS.B2 = 0: Motion Complete
SPOS.B1 = positive edge: Acknowledge start
SPOS.B4 = 1: Drive is moving

Requirements

Device control by PLC/fieldbus
Controller must be in “Operation enabled” status.
A valid record number is active

Tab. 5/23: Parameters involved for Record Select