B. Supplementary information

B-24

Festo P.BE-MTR-DCI-PB-EN en 1209a

Data Memory Control

PNU

127

1...2

0...1

uint8

wo

Description

Commands for the EEPROM (non-volatile data storage)

Delete EEPROM 127

1

0

When the object has been written and after Power Off/On, the data in the
EEPROM is reset to the factory settings.
Fixed: 16 (0x10): delete data in the EEPROM and restore factory settings.

Save Data 127

2

1

The data in EEPROM is overwritten with the current user-specific settings.
Fixed 1 (0x01): save data.

CI access

20F1h

01h...02h

uint8

wo

Note
All user-specific settings will be lost during deletion
(except for cycle number). The status after deletion cor-
responds to the standard factory setting.

Always carry out initial commissioning after deleting the
EEPROM.

The settings of the LCD parameters are lost when the
EEPROM is deleted and may need to be set again. The
LCD display remains dark if the parameter setting is not
correct.

When the EEPROM is deleted, the fieldbus address is
also reset.