B.1.5 overview of parameters – Festo Электромотор MTR-DCI User Manual
Page 219

B. Supplementary information
B-13
Festo P.BE-MTR-DCI-PB-EN en 1209a
B.1.5
Overview of parameters
This overview shows all defined parameters of the FHPP. The
parameters are described in section B.1.7.
Some additional parameters are only available via CI com-
mands; see section B.2.4.
Name
FHPP
CI object
PNU
Subind.
1)
Type
Access
2)
Index
Device data (see section B.1.7).
Standard parameters
Manufacturer Hardware Version BCD
100
–
uint16
ro
2069h
Manufacturer Firmware Version BCD
101
–
uint16
ro
206Ah
Version FHPP
102
–
uint16
ro
2066h
Controller Serial Number
114
1...12
d
char
ro
2072h
Extended parameters
Manufacturer Device Name
120
1...30
d
char
ro
1008h
User Device Name
121
1...8
char
rw
20FDh
Drive Manufacturer
122
1...30
d
char
ro
6504h
HTTP Drive Catalog Address
123
1...30
d
char
ro
6505h
Festo Order Number
124
1...30
d
char
ro
6503h
1)
Subindices of the parameter for FHPP with DPV0 (1...n)
2)
ro = read only, wo = write only, rw = read and write